Not All Double Glazing Is Equal: What Actually Makes a Window Energy Efficient in Australia

not all double glazing is equal

Double glazed is a label, not a performance level

If you’re replacing old single-glazed windows, double glazing may seem like the obvious upgrade. And it can make a significant difference. But choosing double glazing alone doesn’t guarantee a high-performance window.

Double glazing simply means that a window has two panes of glass separated by a sealed cavity. It tells you how many panes the window has — not how well the complete window performs.

Two windows can both be described as double glazed yet perform very differently. Australia’s own NatHERS default values show how wide the gap is: a double glazed, clear, air-filled aluminium window rates Uw 4.8 W/m²K, while a double glazed, low-e, argon-filled timber window rates 2.0. Same label, more than twice the heat loss [1].

As Australia moves away from single glazing — researchers estimate that around 85% of Australian buildings still have it [2] — “double glazed” has become a selling point in its own right. That’s why it’s worth looking beyond the label. The real difference comes down to six things: the frame, the glass and its low-emissivity (low-e) coating, what fills the gap between the panes, the spacer that separates them, how well the unit is sealed, and how airtight the whole window is. This guide explains each one, and the questions to ask before you buy.

Three numbers that matter: Uw, SHGC and visible light

U-value (Uw)

The U-value measures how much heat passes through a window, in watts per square metre per degree of temperature difference (W/m²K). The lower the number, the better the window insulates. There are three versions, and quotes often use the most flattering one:

  • Ug — the centre of the glass only.
  • Uf — the frame only.
  • Uw — the whole window: glass, frame and the edge where they meet. This is the number that reflects what you actually live with.

A good low-e, argon-filled glass unit can have a glass-only value of around 1.0–1.1 W/m²K under the European calculation method (EN 673) [3]. The Australian method typically gives a somewhat higher figure for the same glass [25], but the gap that matters is elsewhere: put that type of glazing into a standard aluminium frame and the NatHERS default for the whole window is 4.1 [1]. The glass hasn’t changed; the frame has taken most of the benefit away.

For perspective, here is what is required in Germany. Under Germany’s building energy law, a replacement window in an existing home must achieve Uw 1.3 W/m²K or better [4], and windows must reach Uw 0.95 W/m²K or better to qualify for the federal renovation subsidy [24]. Both figures are calculated using the European method, so they can’t be compared one-for-one with Australian ratings (see below). Even allowing for that, they show how much higher the building standards for windows are in Germany.

Comparing Australian and European U-values

Important: If a supplier quotes you a U-value, ask which one it is — and which calculation method was used.

Australian and European U-values are not calculated the same way. Australian ratings (AFRC, published through WERS) follow the North American method, which uses colder outdoor test conditions and a smaller standard test window: 600 × 1500 mm, compared with 1230 × 1480 mm in Europe [25][26]. A smaller window has proportionally more frame, so the same window will often rate somewhat higher — that is, worse — in Australia than on a European data sheet.

But it isn’t a fixed offset: research comparing the two methods found whole-window results ranging from about 14% lower to 18% higher [25]. There is no simple conversion, so compare Australian figures with Australian figures, and European with European. We explain the different calculation methods in more detail on our Passive House windows page.

SHGC (solar heat gain coefficient)

SHGC measures how much of the sun’s heat comes through the whole window, on a scale from 0 to 1. Lower means less solar heat — but lower isn’t always better. On exposed west- and east-facing windows, a low SHGC helps prevent overheating. North-facing windows with well-sized eaves can benefit from a higher SHGC, letting in free winter sun while the eaves shade the high summer sun [1]. The right value depends on orientation and climate (see the solar control section below).

Visible light transmittance (VT)

Visible light transmittance (VT) measures how much daylight comes through, also from 0 to 1. A lower SHGC doesn’t automatically mean a dark room, but solar control coatings often reduce daylight too, so glass selection is a balance between the two.

No single number tells you whether a window is right. A window can insulate well and still overheat a west-facing room, or block solar heat well and make a room noticeably darker.

Builder note: WERS (the Window Energy Rating Scheme) reports whole-window values — Uw, SHGCw and air infiltration — for a specific product. A NatHERS assessment that uses a custom window records that product on the certificate, and the window installed must match it.

Why the frame matters

The frame matters as much as the glass. Australia’s government default values show this clearly [1].

In the table below, adding a second pane to a standard aluminium window improves it from 6.7 to 4.8. That still leaves it closer to a single glazed timber window (5.4) than to a well-specified double glazed timber window (2.0). The reason is the frame: aluminium conducts heat very readily, so heat flows around the insulated glass through the frame itself. Better glass alone can’t fix that — which is why two kinds of frame perform so much better: aluminium frames with a thermal break, and frames made from materials that conduct little heat in the first place, such as timber, aluminium-clad timber and uPVC. These don’t need a thermal break.

What is a thermally broken frame?

A thermally broken aluminium frame is made in two parts, inside and outside, joined by an insulating strip — typically a reinforced plastic such as polyamide. The strip interrupts the path heat would otherwise take straight through the metal. In the NatHERS defaults, a thermal break improves a double glazed, low-e, argon-filled aluminium window from Uw 4.1 to 2.9 [1]. That’s a big step, but it’s still behind timber or uPVC with the same glass (2.0).

Australian default values (NatHERS)

Representative values for Group A windows (awning, casement, tilt ‘n’ turn, hinged and French doors), statistically derived from windows on the Australian market [1].

FrameGlazingUw (W/m²K)
AluminiumSingle, clear6.7
AluminiumDouble, clear, air4.8
AluminiumDouble, clear, argon4.5
AluminiumDouble, high-solar-gain low-e, argon4.1
Aluminium, thermally brokenDouble, high-solar-gain low-e, argon2.9
TimberSingle, clear5.4
TimberDouble, clear, air3.0
TimberDouble, high-solar-gain low-e, argon2.0
uPVCDouble, clear, air3.0
uPVCDouble, high-solar-gain low-e, argon2.0

Product example: Amber Windows simulated WERS results

ClimaTrend IV78 tilt & turn window at the Australian test size of 600 × 1500 mm, simulated as required in AS standard. Double glazing is 4 mm / 16 mm argon (90%) / 4 mm with a low-e coating; ranges reflect different coatings.

Tilt & Turn FrameGlazingUw (W/m²K)
European timberDouble, low-e, argon1.46–1.51
Aluminium-clad timberDouble, low-e, argon1.55–1.59
European timberTriple, low-e, argon1.05–1.06
Aluminium-clad timberTriple, low-e, argon1.11–1.13

One more thing stands out in the government figures: adding argon to clear double glazing in a standard aluminium frame moves the window only from 4.8 to 4.5 — a much smaller gain than the thermal break [1].

The figures illustrate how much the complete window system can influence thermal performance. NatHERS default values and product-specific simulations use different bases, so they should not be treated as direct product-to-product comparisons. For a project-specific assessment, request the documented performance of the actual window configuration being specified.

Where aluminium-clad timber fits

Aluminium-clad timber windows have a timber frame on the inside, with a natural timber finish, and an aluminium profile on the outside that takes the weather. Thermal performance comes from the complete system — frame depth, glazing, seals and installation — not from the cladding alone: in Amber’s simulations, adding the cladding changed Uw by less than 0.1 W/m²K [19]. Read more in our guide Aluminium-Clad Timber Windows Explained.

What’s inside a double glazed unit?

A double glazed unit (IGU) is two panes sealed together around a spacer, with a gap between them. Every one of its parts changes how well it performs — and none of them is visible from the outside.

Low-e coating. A microscopically thin metallic layer on one pane that reflects heat. It is one of the most effective upgrades you can make to the glass. With a modern low-e coating and argon, a standard 4/16/4 unit (4 mm glass, 16 mm gap, 4 mm glass) reaches a glass-only Ug of about 1.0–1.1 W/m²K, measured by the European method [3].

The coating does far more than the gas. In UK indicative values for timber or PVC-framed windows with a 16 mm gap (European method), adding low-e lowers the window U-value from 2.7 to 1.8. Adding argon alone moves it only from 2.7 to 2.6 [5].

Coatings come in two main types: high-solar-gain, which lets winter sun in, and low-solar-gain, which keeps summer heat out. The right one depends on climate and orientation.

Cavity width. The gap between the panes matters. In the same indicative values, an air-filled unit with a 6 mm gap gives a window U-value of 3.1, against 2.7 with a 16 mm gap [5]. Units with narrow gaps can still be sold as “double glazed”.

Spacer. The strip that holds the panes apart around the edge. A traditional aluminium spacer conducts heat around the edge of the glass, bypassing the insulated centre. A warm-edge spacer (plastic, composite or stainless steel) conducts far less heat, so less is lost at the edge. That improves the whole window: in one glass manufacturer’s worked example, switching from an aluminium to a warm-edge spacer improved the window U-value by 8–13% [6].

A warmer glass edge also lowers the risk of condensation. In independent testing, edge condensation resistance rose from 19.3 with an aluminium spacer to 44.9 with the best warm-edge spacer [7]. (This is the North American Condensation Resistance rating, which runs from 1 to 100 and has no units. The higher the number, the lower the risk of condensation.)

Edge seal. A primary seal stops moisture getting in and gas getting out; a secondary seal holds the unit together. Small gaps in the primary seal, typically at the corners, let the gas escape and moisture enter — and shorten the life of the unit [8].

Gas fill. Air, argon or (in some triple glazing) krypton. Argon gets its own section below.

Argon: one part of a high-performance glazing system

Argon is a dense, invisible gas sealed between the panes. It slows the movement of heat across the gap, and it is standard in high-performance double and triple glazing. In a low-e double glazed unit, argon can improve the glass’s insulating value by up to about 25% compared with air [8][9]. But argon does its real work alongside a low-e coating. Paired together, they make a high-performance unit; without the coating, argon on its own adds little. And because it’s invisible, you can’t tell by looking whether a unit was ever filled — or how well.

Argon also escapes slowly through the edge seal over time, while air and moisture work their way in. How fast depends on the quality of the seal and the spacer. Studies of early-generation units found many had lost most of their argon [10]; modern European units are tested against long-term gas leakage limits under EN 1279 [11].

For builders: argon works as part of a package

In a high-efficiency unit, argon works as part of a package. Combined with a low-e coating and a warm-edge spacer, it delivers the performance that defines a high-efficiency window. North American industry guidance sets a minimum of 90% argon fill out of the factory, yet independent audits overseas have found production runs as low as 69–74% [8]. Fill levels can be measured without breaking the unit, using laser or spark-emission gas analysers [12]. Ask your supplier not just “is it argon-filled?” but “how is it filled, and is the fill level tested?”

Not every unit is made the same way

Not every double glazed unit is made the same way. Some are still assembled largely by hand, using simpler methods and components. That doesn’t automatically make them poor, but it makes consistency much harder to guarantee: the edge seal is less controlled, the gas fill — if there is one — is harder to verify, and some units are simply filled with air. In fact, air-filled double glazing is common enough in Australia that the government’s rating scheme has a separate category for it [1]. From the outside, all these units look identical, and all can be sold as “double glazed”.

“After more than 20 years working with glazing in Europe and Australia, I’ve seen plenty of units sold as ‘double glazed’ that were air-filled, with a basic aluminium spacer and a weak edge seal. Technically double glazed — but nowhere near a high-efficiency window.”

— Gus Ledauskas, Amber Windows

Airtightness: a window that leaks air can’t insulate

U-values and SHGC are calculated as if the window lets no air through [13]. In reality, air leaking around the sashes carries heated or cooled air straight out of the house — so a well-glazed window that leaks can still feel draughty and waste energy. Airtightness is measured separately, and it is just as important.

How it’s measured in Australia. Windows are tested for air infiltration under AS 4420.4 as part of AS 2047, and the result is reported in litres of air per second per square metre of window (L/s·m²) at a pressure difference of 75 Pa. WERS publishes this figure alongside the U-value and SHGC [14]. AS 2047 sets the maximum air infiltration a window may have [15] — a minimum pass mark, not a sign of a high-performance window. Lower is better. It is also a test result for the window itself, not a guarantee that a room will feel draught-free once the window is installed.

How it’s measured in Europe. Under EN 12207, windows are classified from Class 1 to Class 4, tested at pressures up to 600 Pa, with Class 4 the highest [16]. In a European study of laboratory-tested products, more than 74% of windows reached Class 4 [17].

What makes the difference:

  • Opening type. Hinged windows — casement, awning, tilt & turn — close against compression seals that the wind presses tighter. Sliding windows rely on brush or wipe seals and tend to leak more, although actual performance depends on the tested product [13].
  • Seals and hardware. Multiple continuous gaskets and multi-point locking that pulls the sash evenly into the frame.
  • Manufacturing precision. Corner joints and tolerances that stay tight over years of use.
  • Installation. The joint between the frame and the wall must be sealed too. A perfectly airtight window installed with gaps around it is not an airtight opening.

Ask for the air infiltration figure, and ask whether it was tested on the same window type you are buying.

Installation: where good windows can lose their performance

A window only performs as tested if it is installed as designed. Its air infiltration rating covers leakage through the window itself; leakage around the frame, where it meets the wall, is a separate issue that depends on the installation. Architects and builders should detail:

  • Frame-to-wall sealing — a continuous air seal between the frame and the wall opening.
  • Flashing and water management — so water that gets behind the frame drains out instead of being trapped.
  • Thermal continuity — positioning the frame in line with the wall insulation, so the opening doesn’t become a cold bridge.
  • Connection to the building envelope — linking the window seal to the wall’s wrap or air barrier.
  • The right product — installing the exact configuration and glazing that was specified and rated.

Condensation: on the glass, or inside the unit?

There are two kinds, and they mean different things.

  • On the room-side glass. This forms when the inner glass surface gets cold and indoor humidity is high. Better glazing and a warm-edge spacer keep the inner surface warmer and reduce the risk, especially at the glass edge [7]. But indoor humidity, ventilation and temperature matter too, and no window can guarantee it will never happen.
  • Between the panes. Moisture inside a sealed unit means the edge seal has failed. The unit won’t recover on its own and usually needs replacing — and if moisture can get in, any argon has most likely got out.

Solar control: the number Australian homes often forget

Researchers have found that in Australian homes, up to 87% of summer heat gain comes in through the windows [18]. A low U-value keeps conducted heat out, but it does nothing about direct sunlight. That is measured separately, by the solar heat gain coefficient (SHGC).

SHGC runs from 0 to 1: the lower the number, the less solar heat the window lets in. It is controlled mainly by the glass coating, and it is largely independent of the U-value.

Amber’s own simulation shows how independent. On the same aluminium-clad ClimaTrend IV78 tilt & turn window with the same double glazing, changing only the glass coating moved SHGCw from 0.356 to 0.155 — a 56% cut in solar heat — while Uw stayed essentially unchanged [19].

The trade-off is daylight. The same change in coating also cut visible light transmittance by about 37% [19]:

Glass make-up (outer / cavity / inner)SHGCwVTw
4 mm PlaniClear / 16 mm argon / 4 mm Planitherm XN0.360.46
4 mm Cool-Lite SKN176 / 16 mm argon / 4 mm PlaniClear0.200.40
4 mm Cool-Lite SKN154 / 16 mm argon / 4 mm PlaniClear0.160.29

The strongest solar control glass may be right for a west-facing living room and too dark for a south-facing study.

Match the glass to the orientation:

  • West and east — low SHGC. In Perth, a west-facing room can overheat badly through the afternoon.
  • North — moderate to higher SHGC with properly sized eaves, so low winter sun warms the room while summer sun is shaded.
  • South — focus on a low U-value; direct sun is limited.

A quote that gives one glass type for the whole house has skipped this decision.

Amber Windows figures are simulated (As required in AS, 600 × 1500 mm test size); WERS ratings are not published yet.

What the glass tells you: Australia vs Europe

In Australia, the building code requires safety glass to be marked, either by permanent etching or by a label that can’t be reused. The mark must show the standard the glass was tested to, the manufacturer or supplier, the grade, the thickness and the type of safety glass — for example “T” for toughened or “L” for laminated. That is all safety information: it says nothing about energy performance, the low-e coating or whether the unit is gas-filled. And where a label is used instead of etching, it isn’t intended to stay once construction is finished [20]. Once it’s peeled off, there’s often nothing left on the glass to tell you who made the unit or what’s inside it.

There is also an Australian standard for double glazed units themselves, AS 4666. It covers durability — how well the seal and unit hold up over time — but explicitly excludes thermal, solar, light and acoustic performance [21]. A certified unit is built to last; it is not necessarily efficient. AS4666 test is same as EN1279.

European practice goes further. Many European manufacturers permanently print information on the spacer bar inside the unit — typically the manufacturer, certification and production date, and often the gas fill and glass performance [22]. It stays there for the life of the window. At Amber Windows, our units carry this marking too.

Permanent marking tells you who made the unit and how it was certified. It doesn’t by itself prove the thermal performance of the whole window — for that, ask for the window’s documented Uw and SHGC.

Before you buy “double glazed”: 11 questions to ask

  1. What is the whole-window U-value (Uw), not just the glass (Ug)?
  2. What frame is it: standard aluminium, thermally broken, timber, alu-clad, or uPVC?
  3. Is there a low-e coating, and which type suits each orientation?
  4. Is the unit argon-filled? How is it filled, and is the fill level tested?
  5. What spacer is used: aluminium or warm-edge?
  6. How wide is the gap between the panes?
  7. What are the SHGC and visible light transmittance, especially for west-facing windows?
  8. Is the glass unit certified to AS 4666 or EN1279?
  9. Does this exact product have a WERS rating?
  10. How airtight is the window (air infiltration rating)?
  11. How will the window be installed and sealed into the wall?

A reputable supplier should be able to explain the relevant specifications and provide supporting documentation.

Specifying windows for your next project?

Choosing the right window involves more than selecting double or triple glazing. Frame construction, glass specification, solar control, airtightness and installation details all influence the final result.

At Amber Windows, we work with homeowners, architects and builders to explore high-performance European timber and aluminium-clad timber window and door systems for Australian projects.

aluminium-clad timber windows

Discuss your project with our team to explore the available configurations and the technical documentation relevant to your design.

FAQs

Does the 7-star energy rule mean new homes get good windows?

Not necessarily. WA adopted the 7-star NatHERS minimum on 1 May 2025 [23], but it is a whole-of-house rating: windows are only one part of it, so a 7-star certificate alone doesn’t tell you how good the windows are. The minimum is a floor, not a specification.

Is double glazing worth it in Perth?

It can improve comfort and energy performance, but how much depends on your existing windows, the glass specification, orientation, shading and budget. In Perth, solar control on west- and east-facing windows matters as much as the U-value. We cover this in more detail in our guide Are Double-Glazed Windows Worth It in Australia?

Does argon leak out?

Slowly, through the edge seal. A well-made unit with a quality seal and warm-edge spacer keeps most of its argon for many years; a poorly sealed one can lose it much faster. Fill levels can be checked on site without breaking the unit.

Is triple glazing overkill in Australia?

Not always. In Amber’s own simulations, moving from double to triple glazing improved the whole-window U-value by 24–31% [19]. Whether it’s worth it depends on climate zone, orientation, acoustic needs and budget.

Can I tell what’s in my windows by looking?

No. Low-e coatings can be detected with an inexpensive meter, but argon is invisible. Ask for the documentation: the WERS rating, the glass specification and the IGU certification.

Does double glazing reduce noise?

It can, but acoustic performance is a separate specification from thermal performance. Glass thickness, unequal pane thicknesses, laminated glass, cavity width, frame seals and installation all affect the result. Triple glazing is not automatically quieter than a well-specified double glazed unit — match the specification to the noise problem.

Sources

  1. NatHERS — A guide to windows in NatHERS software (default window values)
  2. Western Sydney University — Thermal performance of retrofitted secondary glazed windows
  3. Pilkington — Optitherm range: Ug 1.0–1.1 W/m²K in a double glazed unit (EN 673)
  4. Energie-Fachberater — German requirements for new windows (Uw 1.3; subsidy 0.95)
  5. Pilkington UK — Indicative U-values for windows with wood or PVC-U frames
  6. Pressglass — Glazed units with warm edge
  7. BuildingGreen — Window performance: dealing with edge losses
  8. Glass Canada — Let’s do a better job on gas fill
  9. RDH Building Science — Argon gas fill technical bulletin
  10. The Snell Group — A unique problem with double-glazed windows
  11. Glass and Glazing Federation — CPR and insulating glass units (EN 1279)
  12. Window & Door — Gas fill 101
  13. Construction Canada — Specifying windows for cold climates
  14. Breezway — Technical bulletin: WERS ratings list U-value, SHGC, light transmittance and air infiltration
  15. Standards Australia, AS 2047:2014 Windows and external glazed doors in buildings (incorporating Amendments 1 and 2)
  16. Q Glass — Air permeability in windows and doors
  17. MDPI Buildings — Air permeability and watertightness of windows and doors
  18. The Conversation via PreventionWeb — Up to 87% of heat gain through windows
  19. Amber Windows — ClimaTrend IV78 thermal simulation, Berkeley Lab WINDOW, NFRC 100-2010 conditions (internal, will be published Nov-Dec 2026)
  20. ABCB — NCC 2022 Housing Provisions Part 8.4, clause 8.4.8 Identification of safety glass
  21. Standards Australia, AS 4666:2012 Insulating glass units (incorporating Amendment 1), Scope, Note 2
  22. Pressglass — Processing and marking of spacer bars
  23. NatHERS News — Western Australia moving to NCC 2022
  24. Verbraucherzentrale NRW — BEG individual measures: technical minimum requirements for windows
  25. RDH Building Science — Energy performance of windows: North American and European standards
  26. CSIRO for the Australian Government — Converting NatHERS tools to use NFRC-based window data (2009)

Gus Ledauskas
Gus Ledauskas

Gus Ledauskas is the founder of Amber Windows and a high-performance window and door systems specialist with over 20 years of experience across Europe and Australia. His background spans timber, aluminium and glazing systems for residential, architectural, commercial and Passive House projects, combining European system expertise with a strong understanding of Australian construction requirements.