High-performance timber and aluminium-clad timber windows designed for energy-efficient Australian homes and Passive House projects.
Thermal performance is only one part of a high-performance window. Frame construction, glazing, airtightness, solar performance and installation all contribute to how a window performs as part of the building envelope.
Passive House sets demanding requirements for the building envelope, and windows are one of its most technically challenging elements. Unlike an insulated wall, a window combines glazing, frame, seals and hardware within a relatively thin building element.
A high-performance window needs to perform as part of the complete building envelope, not simply achieve a low glazing U-value.
The relevant figure is Uw, the thermal transmittance of the complete window, rather than Ug, which describes the glazing alone. Frame performance, glazing and the glazing edge all contribute to the overall result.
SHGC is not simply a “lower is better” metric. The appropriate solar heat gain depends on climate, orientation, glazing area, shading and the overall building design. A specification suitable for one elevation may not be appropriate for another.
Passive House buildings are designed to achieve very high levels of airtightness, with a target of ≤0.6 air changes per hour at 50 Pa (ACH50) for the building. Window seals, hardware and the connection between the window and wall all contribute to achieving this result.
The glazing edge is an important thermal-bridge location. Warm-edge spacers made from low-conductivity materials can reduce heat loss and improve interior surface temperatures compared with conventional metal spacers. The glazing-edge Ψ-value can be incorporated into Passive House calculations.
The way a window connects to the surrounding wall affects its overall thermal performance. Passive House calculations account for the installation thermal bridge, Ψinstallation, which depends on the position of the frame and the surrounding insulation. A high-performance window therefore needs to be considered together with its installation detail.
High-performance windows should maintain sufficiently warm interior surface temperatures to support comfort and help prevent surface condensation and mould. Passive House assessment considers the minimum interior surface temperature and associated hygiene criteria in relation to the construction and project conditions.
A U-value is not simply a fixed number attached to a window. It is the result of a calculation performed under defined conditions.
The reported Uw can be influenced by the calculation method, reference dimensions, glazing specification, frame geometry, spacer and the way the different window components are treated.
This becomes particularly important when comparing European or Passive House window data with Australian WERS data.
For Australian WERS ratings, the standard reference size for casement and tilt & turn windows is 600 × 1500 mm (0.90 m²). European and Passive House calculations commonly use a 1230 × 1480 mm (1.82 m²) reference window.
This means that in Europe the frame itself is a much smaller percentage in comparison to the glass than in Australia, hence another reason why U-values vary.
| European / Passive House data | Australian WERS data | |
| Calculation standards | European CEN standards — EN ISO 10077-1 and -2 for window thermal transmittance, EN 673 for glazing, EN 12631 for curtain walling | AFRC protocols, using the NFRC-derived simulation tools WINDOW 7, Optics 6 and THERM 7 |
| Reference sample size | 1230 × 1480 mm (1.82 m²) window; 2460 × 1480 mm for window systems, per PHI component certification | A defined standard size for each product category, set by AFRC. The casement / tilt & turn category is rated at 600 × 1500 mm (0.90 m²) |
| Whole-window basis | Uw incorporates frame, glazing and glazing-edge effects | WERS assesses whole-window performance, including frame and glazing — not centre-of-glass alone |
| Boundary conditions | European winter conditions | Australian conditions per AFRC |
| Reports | Uw, Ug, Uf, g-value, Ψ-spacer, Ψ-install | Uw, SHGCw, VTw, air infiltration, WERS star ratings |
| Used for | PHPP energy modelling, PHI component certification | NCC / NatHERS compliance, WERS star ratings |
The size difference is important to understand. A smaller reference window has a higher frame-to-glass ratio. Because the frame is generally less insulating than the glazing, this can result in a higher Uw value. The same window configuration can therefore produce a different Uw value when calculated at a different reference size.
This is why a European Uw should not be compared directly with an Australian Uw without understanding the calculation method, reference size and assessment conditions. Neither number is necessarily misleading. They may simply be the result of different methodologies.
Why this matters more than a headline number: A Uw value is only useful for comparison when you know the reference size, calculation standard and assessment status. These details determine how the number should be interpreted and whether it can be used reliably in a building energy model.
You may have seen 0.80 W/m²K quoted as the “Passive House windows U-value”. The reality is more nuanced.
The Passive House Institute (PHI) defines different performance criteria for certified transparent building components according to seven climate zones. The commonly quoted Uw ≤ 0.80 W/(m²K) applies to the Cool-temperate climate zone. The criterion changes for warmer and colder climates

| PHI climate zone | Uw component | Uw installed | Reference glazing Ug |
| Arctic | 0.40 | 0.45 | 0.35 |
| Cold | 0.60 | 0.65 | 0.52 |
| Cool-temperate | 0.80 | 0.85 | 0.70 |
| Warm-temperate | 1.00 | 1.05 | 0.90 |
| Warm | 1.20 | 1.25 | 1.10 |
| Hot | 1.20 | 1.25 | 1.10 |
| Very hot | 1.00 | 1.05 | 0.90 |
Values in W/(m²K). Based on Passive House Institute criteria for certified transparent building components.
There is no single Passive House window U-value that applies across Australia.
The applicable PHI climate zone depends on the project location. It is also important not to confuse PHI climate zones with Australian NCC or NatHERS climate zones, which are different classification systems.
For example, Perth is classified as warm-temperate under the Australian NCC system, and certified Passive House projects in Perth are documented as such. Australian projects span different climatic conditions, so the appropriate window specification needs to be considered for the specific project location rather than applying a single U-value target to the whole country.
The PHI values above are component certification criteria. They should not be interpreted as a universal requirement that every window in a Passive House must achieve the same Uw value.
Passive House is a whole-building performance standard. The building is assessed using the Passive House Planning Package (PHPP), which considers the building’s climate, geometry, orientation, windows, solar gains, shading, insulation, airtightness, ventilation and other factors together.
Window performance is therefore one part of the overall energy balance.
Performance varies with the glazing specification.
| System | Frame | Uw (W/m²K) | SHGCw | VTw | Condensation resistance | Test size |
|---|---|---|---|---|---|---|
| ClimaTrend IV78 Tilt & Turn | Timber | 1.045–1.058 | 0.14–0.29 | 0.26–0.42 | 72.6–73.0 | 600 × 1500 mm |
| ClimaTrend IV78 Tilt & Turn | Aluminium-clad timber | 1.113–1.127 | 0.14–0.29 | 0.26–0.42 | 71.8–72.1 | 600 × 1500 mm |
| Flush Casement 89-69 | Timber | 1.209–1.221 | 0.14–0.27 | 0.23–0.38 | 72.2–72.3 | 600 × 1500 mm |
| Flush Casement 89-69 | Aluminium-clad timber | 1.203–1.215 | 0.13–0.25 | 0.22–0.36 | 73.2–73.3 | 600 × 1500 mm |
| IV78 Door, open-in | Timber | 1.117–1.131 | 0.15–0.30 | 0.27–0.44 | 70.4–70.5 | 1000 × 2000 mm |
| IV78 Door, open-in | Aluminium-clad timber | 1.041–1.055 | 0.15–0.30 | 0.27–0.44 | 71.7–72.1 | 1000 × 2000 mm |
| HS78 Lift & Slide | Timber | 1.087–1.105 | 0.18–0.38 | 0.34–0.55 | 65.5–65.8 | 2000 × 2000 mm |
| HS90 Slim Sliding Door | Timber | 1.326–1.343 | 0.19–0.38 | 0.34–0.55 | 57.8 | 2000 × 2000 mm |
| System | Frame | Uw (W/m²K) | SHGCw | VTw | Condensation resistance | Test size |
|---|---|---|---|---|---|---|
| ClimaTrend IV78 Tilt & Turn | Timber | 1.464–1.505 | 0.16–0.36 | 0.30–0.47 | 57.9–58.6 | 600 × 1500 mm |
| ClimaTrend IV78 Tilt & Turn | Aluminium-clad timber | 1.552–1.593 | 0.16–0.36 | 0.29–0.46 | 58.1–58.7 | 600 × 1500 mm |
| Flush Casement 89-69 | Timber | 1.595–1.632 | 0.15–0.33 | 0.27–0.43 | 59.9–60.6 | 600 × 1500 mm |
| Flush Casement 89-69 | Aluminium-clad timber | 1.574–1.609 | 0.14–0.31 | 0.25–0.40 | 59.1–59.8 | 600 × 1500 mm |
| IV78 Door, open-in | Timber | 1.545–1.589 | 0.16–0.38 | 0.31–0.49 | 57.3–57.8 | 1000 × 2000 mm |
| IV78 Door, open-in | Aluminium-clad timber | 1.493–1.536 | 0.16–0.37 | 0.31–0.49 | 57.6–58.1 | 1000 × 2000 mm |
| HS78 Lift & Slide | Timber | 1.611–1.666 | 0.20–0.47 | 0.39–0.61 | 55.3–55.7 | 2000 × 2000 mm |
These are WERS whole-window ratings, calculated under Australian Fenestration Rating Council protocols at the standard rating sizes shown. Public listing in the WERS database follows in November 2026.
Not as a rule.
Triple glazing is usually how a window reaches Passive House U-values in cooler climates, and it brings acoustic and comfort benefits that clients notice. But there is no glazing specification that is correct for every project. The optimum depends on climate zone, orientation, glazing area, shading, and what the building’s energy model actually needs.
In warmer Australian climates, solar control and shading strategy frequently do more work than the third pane. Window specification should come out of the energy model, not ahead of it
A high-performance window is only as good as the junction it sits in. The threshold, in particular, has to be resolved against finished floor levels, external surfaces and the waterproofing line at design stage — not negotiated on site.
We publish installation details showing how our systems interface with surrounding construction, including slab, waterproof membrane, shims and sealant, for both internal-flush / 0 mm threshold and internal-flush / 25 mm external step-down conditions, across Lift & Slide Doors, Tilt & Turn Windows and Hinged Doors.

Our systems are built around deep timber frames, high-performance glazing and airtight construction. For Australian projects we provide whole-window performance data, installation details and project-specific configuration support, and we are progressing products through Australian rating so architects and assessors have locally relevant figures to work with.
If you’re modelling a Passive House or low-energy project, we can supply configuration-specific performance data for your schedule.
Passive House windows are high-performance windows specified to support the thermal, solar, airtightness and thermal-bridge requirements of a Passive House project. Their performance needs to be considered as a complete assembly, including the frame, glazing, glazing edge and installation, rather than the glass alone.
It depends on the Passive House climate zone and the specific project. The Passive House Institute publishes component criteria across seven climate zones, with different U-value limits for each. The widely quoted 0.80 W/(m²K) figure applies to the Cool-temperate climate zone and is not a universal requirement for all Passive House windows. The performance requirements for an individual project are evaluated as part of the overall building design and energy model.
Not directly. European and Australian window performance can be calculated under different standards, boundary conditions and reference sizes. A Uw value should therefore always be considered together with the methodology, reference size, window configuration and assessment status before comparing products.
Yes. Timber has relatively low thermal conductivity, making it well suited to high-performance window frames. Deep timber frames are commonly used in Passive House projects, although suitability depends on the complete window configuration, glazing and installation.
They can be. Aluminium-clad timber windows combine a timber frame with an external aluminium protective layer. The thermal performance depends on the construction of the complete system and its configuration, so whole-window performance should be assessed rather than assumed from the materials alone.
No. Triple glazing is common in cooler climates because it can provide strong thermal performance, but it is not a universal Passive House requirement. The appropriate glazing specification depends on the climate, orientation, solar exposure, shading and the overall building energy model.
Ug describes the thermal transmittance of the glazing alone. Uf describes the frame. Uw describes the thermal transmittance of the complete window, including the frame, glazing and glazing-edge effects. Uw is therefore the relevant whole-window value when assessing window performance in a building energy model.
No. “Double glazed” only tells you a window has two panes of glass. In Australia’s NatHERS default values, a double glazed aluminium window with clear glass rates Uw 4.8 W/m²K, while a double glazed timber window with low-e glass and argon rates Uw 2.0 W/m²K. That’s more than twice the heat loss under the same label. The difference comes from the frame, the low-e coating, the gas fill, the spacer and how airtight the window is. We explain each one in what makes double glazing energy efficient.